AMRCTL(8) System Manager's Manual AMRCTL(8)

NAME

amrctlControl utility for AMI MegaRaid controllers

SYNOPSIS

amrctl stat [-bgv] [-a attempts] [-f device] [-l volno] [-p driveno] [-s busno] [-s busno:driveno] [-t microseconds]

DESCRIPTION

The amrctl queries or controls AMI MegaRaid controllers supported by the amr(4) driver.

Only the stat subcommand is currently implemented, and reports status of the controller. The options for the stat subcommand are as follows:

-a attempts
Number of retries for a command before giving up. Default 5.
-b
Report battery status.
-f device
Device to use. Default to /dev/amr0.
-g
Report global paramters for the controller.
-l volno
Report status of a logical drive.
-p driveno
Report status of a physical drive.
-s busno
Report status of all physical drives on the specified bus.
-s busno:driveno
Report status of the specified physical drive on the specified bus.
-t microseconds
Delay between retries for a command.
-v
Increase verbosity level by one.

SEE ALSO

amr(4)

HISTORY

The amrctl command first appeared in NetBSD 4.0.

AUTHORS

The amrctl command was written by Pierre David <Pierre.David@crc.u-strasbg.fr> and Jung-uk Kim <jkim@FreeBSD.org> for FreeBSD.
July 22, 2006 NetBSD 6.1